Loading...
11/10/2020 Ordinances 9802ORDINANCE NO. 9802 An ordinance to amend Chapter 8 of Grand Island City Code; to amend Sections 8-1 — 5, 8-7, 8-20.1 and 8-21; to clarify and/or make general corrections to various code sections, to repeal any ordinance or parts of ordinances in conflict herewith; and to provide for publication and the effective date of this ordinance. BE IT ORDAINED BY THE MAYOR AND COUNCIL OF THE CITY OF GRAND ISLAND, NEBRASKA: SECTION 1. Sections 8-1 — 5, 8-7, 8-20.1 and 8-21 of the Grand Island City Code Chapter 8 are amended to read as follows: §8-1. International Building Code (IBC) Adopted The International Building Code, 2018 Edition, published by the International Code Council, is hereby adopted, together with any amendments thereto as may be made from time to time, except such portions as are hereinafter deleted, modified, or amended by ordinance and set forth in this chapter of the City Code. The following sections of the Appendix shall also be adopted: Appendix C Group U— Agricultural Buildings Appendix I — Patio Covers One copy of the International Building Code, 2018 Edition, and all supplements or amendments thereto shall be filed in the office of the city clerk as provided by law. §8-2. International Residential Code (IRC) Adopted The International Residential Code, 2018 Edition, published by the International Code Council, is hereby adopted, together with any amendments thereto as may be made from time to time, except such portions as are hereinafter deleted, modified, or amended by ordinance and set forth in this chapter of the City Code. One copy of the International Residential Code, 2018 Edition, and all supplements or amendments thereto shall be filed in the office of the City Clerk as provided by law. §8-3. International Building Code (IBC) and International Residential Code (IRC); Standards Adopted The following standards shall be used with the International Building Code and the International Residential Code adopted by §8-1 and §8-2 above: Acceptable Wind Load Design Procedures: 2018 I.B.C. - Basic Wind Speed The ultimate design wind speed shall be 120 mph, in risk category II,III,&IV. Approved as to Form tt November 9, 2020 � Ci Attomey ORDINANCE NO. 9802 (Cont.) Exposure C only Roof Snow Load - 30 pounds per sq. ft. Frost Depth - 36 inch minimum Seismic Design Category A, Site Class D IRC, Table R301.5 Amend live load for sleeping rooms from 30 pounds to 40 pounds per square foot. §8-4. IBC - Certain Sections Not Adopted It is especially provided that the following chapters, sections, and tables of the International Building Code are not adopted or approved, and the same shall be of no force and effect: Chapter 1 Section 101.4.1 Gas Section 101.4.2 Mechanical Section 101.4.3 Plumbing Section 101.4.4 Property Maintenance Section 101.4.6 Energy Section 103 Department of Safety Section 106 Floor and Roof design Loads Section 107.2.6.1 Design Flood Elevations Section 108 Temporary Structures and Uses Section 113 Board of Appeals Chapter 13 — Energy Efficiency Section 1612 Flood Loads Section 1809.5 — Frost Protection; #2 Constructing in accordance with ASCE-32, and Exception: 1,2,3. Chapter 27 — Electrical Chapter 28 — Mechanical Chapter 30 — Elevators and Conveying Systems Chapter 32 — Encroachments into the Public Right-of-Way Chapter 33 — Safeguards During Construction Chapter 34 — Reserved Appendix A Employee Qualifications Appendix B Board of Appeals Appendix D Fire Districts Appendix E Supplementary Accessibility Requirements Appendix F Rodent Proofing Appendix G Flood-Resistant Construction Appendix H Signs Appendix J Grading Appendix K Administrative Provisions Appendix L Earthquake Recording Instrumentation Appendix M Tsunami-Generated Flood Hazard Appendix N Replicable Buildings -2- ORDINANCE NO. 9802 (Cont.) Sechon R403.1.4.1 Frost Protection; 2. Constructing in Accardance with Section R403.3 Section R403.1.4.1 Frost Protection; 3. Constructing in Accordance with ASCE 32. Section R403.1.4.1 Frost Protection; Exceptions: 1, 2, & 3 existing buildings m flood hazard areas. Section R107 — Temporary Structures and Uses Section R109.1.3 — Floodplain Inspections Section Rl 12 — Board of Appeals Section 313 Automatic Fire Sprinkler Systems Section R322 — Flood-Resistant Construction §8-5. IRC — Certain Sections and Parts Not Adopted It is especially provided that the following parts, chapters, and sections of the International Residential Code are not adopted or approved, and the same shall be of no force and effect: Section R105.3.1.1 Determination of Substantially improved or substantially damaged Section R403.3 — Frost Protected Shallow Foundations Section R403.3.1 — Foundations Adjoining Frost Protected Shallow Foundations Section R4033.1.1 — Attachment to Unheated Slab-on Ground Structure Section R403.3.1.2 — Attachment to Heated Structure Section R403.3.2 — Protection of Horizontal Insulation Below Ground Section R403.3.3 — Drainage Section R403.3.4 — Termite Protection Section R406.2 — Concrete and masonry foundation waterproofing Part IV - Energy Conservation Part V - Mechanical Part VI - Fuel Gas Part VII — Plumbing Part VIII — Electrical Appendices, A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S &T §8-7. International Existing Building Code (IEBC) Adopted The International Existing Building Code, 2018 edition, published by the International Code Council is hereby adopted. One copy of the International Existing Building Code, 2018 edition, shall be filed in the office of the City clerk as provided by law. §8-20.1. IRC Section R908 & IBC Section 1511 Reroofing R908.3.2.2 & 1511.3.1 Roof recover not allowed. Amend by adding #2. Wood, wood shake, asphalt, & fiberglass. R908.3.1 & 1511.3.1, Roof recover. Delete #1. 8-21. Buildings Having Historical Significance Buildings or structures which have been designated by official action of the Grand Island City Council as having special historical or architectural significance may comply with Chapter 12 of the 2018 International Existing Building Code for historic buildings. Historical buildings shall be buildings which are currently listed on the National Register of Historical Buildings or are at least fifty years old and have one of the following -3- ORDINANCE NO. 9802 (Cont.) characteristics: is associated with an important person or event which has contributed significantly to history, contains significant architectural or artistic design, or has significant archeological properties. SECTION 2. Any ordinance or parts of ordinances in conflict herewith be, and hereby are, repealed. SECTION 3. This ordinance shall be in force and take effect from and after its passage and publication pursuant to law beginning January 1, 2021. Enacted: November 10, 2020. :.�. • �.,..�-� Roger . Steele, Mayor Attest: o� GRANp �s �0.� C� o ��L ci?'+ �G�E�'�RATFp�2a RaNae Edwards, City Clerk .�. � .► • -� � * i ' �F� 10, ���� r �''t. .�•' �EBRAS�P �